Abstract

The pulse stretcher ring ELSA delivers polarized and non-polarized electrons with an adjustable beam energy of 0.5–3.5GeV to external experimental stations. To meet the growing demands of the user community regarding beam intensity and quality, the upgrade of vital accelerator components is an ongoing process. This includes the improvement of the beam diagnostics in order to resolve and monitor intensity and quality limiting effects. ELSA has recently been equipped with a diagnostic synchrotron radiation beamline housing a streak camera as main beam imaging device. It extends the diagnostics capabilities into the picosecond temporal resolution regime and captures fast longitudinal and transverse beam dynamics. The obtained measurements provide crucial feedback for further machine optimization. The overall performance of the streak camera system and machine relevant measurements are presented.