Abstract
PurposeThis paper aims to focus the synchronous chemical conversion technology–based titanium/zirconium composite on 6061, 7075 aluminum alloys and galvanized steel.Design/methodology/approachThe effects of pH, temperature, reaction time and other process parameters on the corrosion resistance of the three metal surface coatings were investigated by copper sulfate drop and electrochemical corrosion performance tests under a certain content of H2TiF6 and H2ZrF6. The surface morphology and element distribution of the conversion coating were analyzed by scanning electron microscope and X-ray photoelectron spectroscopy.FindingsThe results show that the optimal synchronization chemical conversion conditions of 6061/7075 aluminum alloys/galvanized steel are controlled as follows: H2TiF6 2.2 mL/L, H2ZrF6 1 mL/L, pH 3.9, conversion temperature 35°C and conversion time 120 s.Originality/valueMulti-metals chemical conversion coating can be obtained simultaneously with uniform corrosion resistance and surface morphology. The presence of microdomain features in multiple metals facilitates simultaneous chemical conversion into coatings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.