Abstract

The digital control of three-level voltage source inverter fed high power high performance ac drives has recently become a popular in industrial applications. In order to control such drives, the pulse width modulation algorithm needs to be implemented in the controller. In this paper, synchronized symmetrical bus-clamping pulse width modulation strategies are presented. These strategies have some practical advantages such as reduced average switching frequency, easy digital implementation, reduced switching losses and improved output voltage quality compared to conventional space vector pulse width modulation strategies. The operation of three level inverter in linear region is extended to overmodulation region. The performance is analyzed in terms THD and fundamental output voltage waveforms and is compared with conventional space vector PWM strategies and found that switching losses can be minimized using bus-clamping strategy compared to conventional space vector strategy. The proposed method is implemented using Motorola Power PC 8240 processor and verified on a constant v/f induction motor drive fed from IGBT based inverter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.