Abstract
Laser triggering was used to synchronize the switching of two resonant microwave compressors over to energy extraction mode. The obtained experimental data of the study are presented. Practically the precise synchronism was demonstrated when switching the working mode in the storage regime. Each compressor provided pulses of 250 MW power and 5 ns pulsewidth, the pulse summation gave the output pulse power of 500 MW. Foundation of the supposition that the combined power of several compressors with common load can exceed 1 GW when laser radiation synchronized operation is given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.