<h3>OBJECTIVES</h3> To characterise the distribution of particle size and mass of glove powder aerosol released from powdered and powder free non-sterile latex gloves under controlled conditions. <h3>METHODS</h3> Gravimetric sampling and aerodynamic particle size analysis were performed during simulated use of gloves on a prosthetic hand in a chamber designed to minimise background particle concentrations. <h3>RESULTS</h3> Aerosol was detectable for both powdered and powder free gloves under both aggressive and non-aggressive handling conditions. Most of the particles detected had aerodynamic diameter less than 10 μm. <h3>CONCLUSION</h3> Powder free gloves were not entirely free of powder aerosol. Particles from both powdered and powder free gloves are sufficiently fine to penetrate into the thoracic region of the respiratory tract.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.