Abstract
Piezoelectric actuators exhibit large hysteresis between the applied voltage and their displacement. A switched capacitor charge pump is proposed to reduce hysteresis and linearize the movement of piezoelectric actuators. By pumping the same amount of charges into the piezoelectric actuator quantitatively, the actuator will be forced to change its length with constant step. Compared with traditional voltage and charge driving, experimental results demonstrated that the piezoelectric stack driven by the charge pump had less hysteresis over a large frequency range, especially at ultralow frequencies. A hysteresis of less than 2.01% was achieved over a frequency range of 0.01-20 Hz using the charge pump driver.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.