Abstract
Presented within this dissertation is the evolution of the research leading to the selection of small, low power architectural solutions to the University of Rhode Island’s (URI) Neural Machine Interface (NMI) algorithm. The NMI is designed to provide volitional control of an artificial limb for transfemoral amputees. The NMI algorithm is based on neuromuscular–mechanical fusion, gait phase dependent, nonlinear support vector machine (SVM) classification. URI’s NMI algorithm utilizes electromyography to detect direct commands from the human brain to the residual thigh muscles in conjunction with mechanical signals derived from loadcell to determine the user’s intended locomotion mode. Of utmost importance is the classification accuracy, since any misclassification can cause the user to stumble, possibly leading to serious injury or death. Furthermore, of importance is the development of a small and low power architectural solution, such that it can be included within the confines of the artificial limb. URI has tackled both these challenges, leading to its mobile Central Processing Unit (CPU) solution. The mobile CPU solution was the first solution with sufficient processing throughput to execute the NMI at 20ms window increments. This led to a steady state classification accuracy of 99.94%, during real-time testing, with an able bodied subject. This testing included a total of 14000+ static classifications, and is currently URI's only, 20ms window increment, state of the art algorithmic and architectural solution to undergo real time human subject testing and evaluation. In contrast to URI’s NMI algorithm, other state of the art algorithms provide volitional control through either echo control or solely thru intrinsic mechanical feedback. In echo control, sensors are placed within the sound leg to determine the intended locomotion mode. In most cases these sensors typically communicate wirelessly with the artificial limb to provide the feedback necessary for volitional control. This approach is disadvantaged in the fact that it requires that sensors be instrumented on the sound limb, the user must always lead with the sound limb, and the wireless communications may possibly be jammed. Current algorithms based solely on intrinsic mechanical feedback, have been shown to provide high accuracy, but have had difficulty dealing with more than two simultaneous dynamic locomotion modes (e.g. - walk, stair up, stair down, ramp up, and ramp down). Clearly URI's NMI solution has advantages over other state of the art powered lower limb prosthetic control algorithms. It provides volitional control without the need to instrument the sound limb,
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have