Abstract
The serum theophylline concentration profiles and clinical efficacy of two sustained-release theophylline tablets (Quibron-T/SR and Theo-Dur) were compared in 13 asthmatic children requiring continuous theophylline therapy. Quibron-T/SR and Theo-Dur, administered every 12 hours in the same dose for one week, were evaluated in a multiple-dose randomized crossover study. At the end of each week, serial serum theophylline concentrations were measured and spirometry and body plethysmography were performed. No significant differences between treatments were found in bioavailability, adverse effects, clinical symptom scores, or pulmonary function in spite of the fact that Quibron-T/SR and Theo-Dur produced significantly different serum theophylline concentration profiles as measured by a mean percent of fluctuation in serum theophylline levels of 143 for Quibron-T/SR and 65.7 for Theo-Dur. Over the short term of the study the pharmacokinetic differences did not produce significant differences in clinical efficacy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.