Abstract

This paper presents the results of measurements the suspended particles of the PM 10 and PM 2.5 fractions in two high schools in Bor (School of Mechanical and Electrical Engineering-MS and Grammar School-GM). The measurements were conducted in two heating seasons for a duration of seven days (five weekdays, and two weekend days). Periods during the weekdays when there were classes and weekend days when there were no classes at school were analyzed separately. The measurement results show that the average concentrations of suspended particles PM 10 during the class period were 1.7 (GM) and 2.4 (MS) times higher than in the period without classes. The average concentrations of suspended particles PM 2.5 in both schools during the class period were 1.5 times higher than in the period without classes. In MS the average PM 10 and PM 2.5 concentrations during classes were above daily limit values for 3 of 5 working days. In contrast, there was no exceeding of the average daily limit values for concentrations of suspended particles during classes in GM. The results of measurements indicate that more attention should be paid to the way classrooms are cleaned to reduce the possibility of particles resuspension due to the movement of pupils during the teaching period.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.