The malfunction rates of and trends in various cerebrospinal fluid (CSF) shunt designs have been widely studied, but one area that has received little attention is the comparison of the peritoneal distal slit valve (DSV) shunt to other conventional valve (CV) type shunts. The literature that does exist comes from older case series that provide only indirect comparisons, and the conclusions are mixed. Here, the authors provide a direct comparison of the overall survival and failure trends of DSV shunts to those of other valve type shunts. Three hundred seventy-two new CSF shunts were placed in pediatric patients at the authors' institution between January 2011 and December 2015. Only ventriculoperitoneal (VP) shunts were eligible for study inclusion. Ventriculoatrial, lumboperitoneal, cystoperitoneal, subdural-peritoneal, and spinal shunts were all excluded. Rates and patterns of shunt malfunction were compared, and survival curves were generated. Patterns of failure were categorized as proximal failure, distal failure, simultaneous proximal and distal (proximal+distal) failure, removal for infection, externalization for abdominal pseudocyst, and addition of a ventricular catheter for loculated hydrocephalus. A total of 232 VP shunts were included in the final analysis, 115 DSV shunts and 117 CV shunts. There was no difference in the overall failure rate or time to failure between the two groups, and the follow-up period was statistically similar between the groups. The DSV group had a failure rate of 54% and a mean time to failure of 17.8 months. The CV group had a failure rate of 50% (p = 0.50) and a mean time to failure of 18.5 months (p = 0.56). The overall shunt survival curves for these two groups were similar; however, the location of failure was significantly different between the two groups. Shunts with DSVs had proportionately more distal failures than the CV group (34% vs 14%, respectively, p = 0.009). DSV shunts were also found to have proximal+distal catheter occlusions more frequently than CV shunts (23% vs 5%, respectively, p = 0.005). CV shunts were found to have significantly more proximal failures than the DSV shunts (53% vs 27%, p = 0.028). However, the only failure type that carried a statistically significant adjusted hazard ratio in a multivariate analysis was proximal+distal catheter obstruction (CV vs DSV shunt: HR 0.21, 95% CI 0.05-0.81). There appears to be a difference in the location of catheter obstruction leading to the malfunction of shunts with DSVs compared to shunts with CVs; however, overall shunt survival is similar between the two. These failure types are also affected by other factors such etiology of hydrocephalus and endoscope use. The implications of these findings are unclear, and this topic warrants further investigation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.