Abstract
Objective: To determine the surface roughness and surface hardness difference in composite resin provisional crown before and after brushing with whitening toothpaste.
 Material and Methods: This was a pre- and post-test group design experimental study. In this study, the sample was a composite resin provisional crown based on bis-acryl. The number of samples in this study was 32 samples, 16 for the surface roughness test and the other 16 for the surface hardness test. Each sample was brushed using a V8-Brushing Machine Modified, then tested for surface roughness and hardness using a Profilometer and Vickers Hardness Tester.
 Results: The paired T test was used to analyze the results statistically. There was a significant difference between the groups before and after brushing with whitening toothpaste. (p<0.05).
 Conclusion: After simulated brushing with whitening toothpaste, there was a change in the the provisional crown material surface roughness and hardness value.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.