Abstract

In this paper, we introduce a z-axis quartz gyroscope using a double-H tuning fork, which has a high sensitivity. However, it also causes a large mechanical quadrature error. The laser trimming method is used to suppress this error at quartz level. The trimming law is obtained through the finite element method (FEM). A femtosecond laser processing system is used to trim the gold balancing masses on the beams, and experimental results are basically consistent with the simulated ones. The mechanical quadrature error is suppressed by 96%, from 26.3° s−1 to 1.1° s−1. Nonlinearity changes from 1.48% to 0.30%, angular random walk (ARW) is reduced from 2.19° h−1/2 to 1.42° h−1/2, and bias instability is improved by a factor of 7.7, from 197.6° h−1 to 25.4° h−1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.