Abstract
The main energy consumers in sewer networks are the sewage pumps. Therefore, to minimize the energy consumption, it is essential that these pumps operate under satisfactory conditions. Knowledge about the efficiency of the pumps and their operating conditions can help the pump station management to operate the system optimal. In the search for innovative solutions that can help the sewer management with this information, we propose a method that provides information on the pump flows, the inflow to a sewage pit, and an online estimate of the efficiency of the pump. All these information are obtained without a flow sensor. We argued that the calculated flow values can be used by the sewer management to optimize the operation on the sewer pumps, and the efficiency estimate can be used for optimal scheduling of maintain procedures. The flow and the efficiency estimations are exemplified on a pumping station of the sewer network in Herning, Denmark.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.