Abstract

In recent times, photovoltaic (PV) power generation has been growing due to increase in energy demand. In grid-connected mode, achieving maximum power (MP) from the PV array is difficult by using conventional techniques due to various reasons like low tracking efficiency, stability issues, etc. This motivates the design of an appropriate control strategy to obtain the maximum power point tracking (MPPT) to harvest MP from the PV array. This paper proposes a combined higher order sliding mode observer (HOSMO)–super-twisting control (STC) for a grid-connected scenario. A perturb and observe (P &O) technique is employed to generate reference voltage, and a HOSMO is proposed to drive the STC by estimating the inductor current of the PV boost converter. The proposed controller performance is evaluated based on response time across various scenarios, including generation changes, dynamic faults, islanding and resynchronization, and load variations in comparison to other existing controllers. These microgrid test cases have been thoroughly simulated, and their effectiveness has been validated in real-time using OPAL-RT (OP4510).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.