Abstract

How a glass-curtain wall affects the heating and cooling load of a building is analysed. The study includes five types of glazings, which include double-glazed clear glass, double-glazed low-e, and double-glazed solar control. The analysis is for three climates: composite (New Delhi), hot and dry (Jodhpur), and warm and humid (Chennai). An office building is chosen for analysis. The study includes effect of glazed area, orientation, and that of climates, on annual energy consumption. It was found that energy consumption increases linearly with the glazed area and minimum energy consumption is for north orientation. For types of climates considered in this study, a glass-curtain wall, made of solar control glazing (reflective), consumes 6–8% less energy than the standard window.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.