Abstract

The object of the study was to evaluate the suitability and trueness of the removable partial denture (RPD) framework fabricated by polyether ether ketone (PEEK) with the CAD-CAM technology in vitro. Four different types of dentition defects were selected. In each type, five PEEK RPD frameworks were fabricated by the CAD-CAM technology, while five Co-Cr RPD frameworks were made by traditional casting. The suitability of the framework was evaluated by silicone rubber film slice measurement and the three-dimensional image overlay method. The trueness of the PEEK framework was detected by the three-dimensional image overlay method. Data were statistically analyzed with the use of an independent samples t-test (α = 0.05). The suitability values by silicone rubber film slice measurement of the PEEK group were lower than those of the Co-Cr group in four types, with the differences indicating statistical significance (p < 0.05) in type one, type two, and type four. The suitability values using the three-dimensional image overlay method showed no statistical differences (p > 0.05) between the two groups in four types. The trueness values of the PEEK group were within the allowable range of clinical error. The suitability and trueness of the PEEK RPD framework fabricated by CAD-CAM technology met the requirements of the clinical prosthesis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call