Abstract

Purpose: To realise a full 3D heterogeneous dose calculation for total body irradiation (TBI) cases treated with a translating couch technique and to compare different treatment planning tools. Method and Materials: A retrospective study was performed on 7 patients. Dose distributions obtained with Pinnacle3 v.7.9u (Philips Medical Systems) were compared with those calculated with our actual TBI planning system Theraplan Plus (TPP) by MDS Nordion/Nucletron. Two different Pinnacle3 models were studied: standard beam commissioning (std_Pinnacle3) and TBI commissioning (TBI_Pinnacle3). For the later case, the commissioning was adapted for TBI and its special conditions (extended SSD of 190cm, large field, acrylic beam spoiler, and out of field dose (OFD)). Results: The retrospective study on 7 patients showed significant differences between TPP, std_Pinnacle3 and TBI_Pinnacle3 dose distributions. Relative homogeneous mid‐line doses were compared. Differences up to 12% were obtained and a systematic overestimation of 5% was found in patients extremities (e.g.: head and legs) between TPP and TBI_Pinnacle3. Average dose underestimation of 3% was observed between std_Pinnacle3 and TBI_Pinnacle3. Differences in patient extremities are attributed to the OFD contribution which is not correctly computed in TPP and std_Pinnacle3. Dose comparison outside the patient mid‐line showed greater differences (up to 20%) between models. Because only TBI_Pinnacle3 takes into account the beam spoiler effect, other models underestimate shallow doses. An accurate 3D heterogeneous dose calculation is possible with TBI_Pinnacle3 model. Results showed major differences (homogeneous versus heterogeneous) in high and low density regions as bones and lungs. Dose overestimation of 5% was observed in bone regions and dose underestimation of 5% to 10% was observed in lung regions. Conclusion: Those results are of major interest since, depending on the treatment planning system and its beam commissioning, it could lead to significant dose misevaluation. Heterogeneous dose calculation should be performed with TBI specific beam commissioning.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.