Abstract

Intracardiac thrombus occurs in 1.2%-6.3% of patients undergoing orthotopic liver transplant and is associated with a high mortality rate. The pathophysiology and risk factors for development of this complication are not well understood. No consensus treatment guidelines exist, and specific therapies are associated with serious risks. We present the timely and successful use of a Poole tip surgical suction device advanced into the right atrium through a cavotomy created in the inferior vena cava to remove a large right atrial thrombus during liver transplant. The thrombus was identified with transesophageal echocardiography and was causing cardiovascular collapse.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.