Abstract

BackgroundCardiac resynchronization therapy (CRT) is generally associated with a low to moderate increase of the left ventricular ejection fraction (LVEF). In some patients, however, LVEF improves remarkably and reaches near-normal values. The aim of the present study was to further characterize these so called 'super-responders' with a special focus on the extent of intra- and interventricular asynchrony before and after device implantation compared to average responders.Methods37 consecutive patients who underwent CRT device implantation according to current guidelines were included in the study. Patients were examined by echocardiography before, one day after and six months after device implantation. Pre-defined criterion for superior response to CRT was an LVEF increase > 15% after six months.ResultsAt follow-up, eight patients (21.6%) were identified as super-responders. There were no significant differences regarding age, gender, prevalence of ischemic heart disease and LVEF between average and super-responders at baseline. After six months, LVEF had significantly increased from 26.7% ± 5.7% to 33.1% ± 7.9% (p < 0.001) in average and from 24.0% ± 6.7% to 50.3% ± 7.4% (p < 0.001) in super-responders. Both groups showed a significant reduction of QRS duration as well as LV end-diastolic and -systolic volumes under CRT. At baseline, the interventricular mechanical delay (IVMD) was 53.7 ± 20.9 ms in average and 56.9 ± 22.4 ms in super-responders - representing a similar extent of interventricular asynchrony in both groups (p = 0.713). CRT significantly reduced the IVMD to 20.3 ± 15.7 (p < 0.001) in average and to 19.8 ± 15.9 ms (p = 0.013) in super-responders with no difference between both groups (p = 0.858). As a marker for intraventricular asynchrony, we assessed the longest intraventricular delay between six basal LV segments. At baseline, there was no difference between average (86.2 ± 30.5 ms) and super-responders (78.8 ± 23.6 ms, p = 0.528). CRT significantly reduced the longest intraventricular delay in both groups - with a significant difference between average (66.2 ± 36.2 ms) and super-responders (32.5 ± 18.3 ms, p = 0.022). Multivariate logistic regression analysis identified the longest intraventricular delay one day after device implantation as an independent predictor of superior response to CRT (p = 0.038).ConclusionsA significant reduction of the longest intraventricular delay correlates with superior response to CRT.

Highlights

  • Cardiac resynchronization therapy (CRT) is generally associated with a low to moderate increase of the left ventricular ejection fraction (LVEF)

  • Superior response to CRT was defined as an LVEF increase > 15% six months after implantation

  • Super-responders showed significantly better LV geometry and systolic function compared to average responders

Read more

Summary

Introduction

Cardiac resynchronization therapy (CRT) is generally associated with a low to moderate increase of the left ventricular ejection fraction (LVEF). The aim of the present study was to further characterize these so called ‘super-responders’ with a special focus on the extent of intra- and interventricular asynchrony before and after device implantation compared to average responders. Conduction disorders such as left bundle branch block (LBBB) are a common finding in patients with chronic heart failure (CHF) and frequently result in intra- and/ or interventricular asynchrony [1]. Cardiac resynchronization therapy (CRT) aims at reverse remodeling by biventricular pacing and has been demonstrated to remarkably improve morbidity and mortality in CHF patients [2,3,4]. Patient selection for CRT is currently based only on LVEF, QRS duration and NYHA class [7]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.