Abstract

The primary objective of this study was to compare the radiological and clinical results of anterograde and retrograde screwing in subtalar arthrodesis using a single compression screw. The secondary objective was to evaluate the subjective results and consolidation of this procedure. The hypotheses were that isolated screw fixation was sufficient to achieve good consolidation and that there was no difference between the two techniques with a similar rate of bone fusion. This is a monocentric, retrospective, radio-clinical study based on 99 patients (101 feet), 58 males and 41 females, with an average age of 64years. The main aetiology was post-traumatic osteoarthritis, which represented 51% of cases. Two groups were formed: group A (52 feet) consisting of fixed arthrodesis with ascending (retrograde) screwing and group D (49 feet) consisting of fixed arthrodesis with descending (anterograde) screwing. The two groups were statistically comparable in terms of demographic data as well as aetiologies and comorbidities. Arthrodeses which were not fused at 6months were reassessed at one year and in the event of any radio-clinical doubt regarding consolidation, an additional CT scan was prescribed. Average post-operative follow-up was 11 ± 5years (2-27years). Ninety-two arthrodeses (93%) were fused at one year and 9 were considered to be in non-union, 5 (9.8%) in group A, and 4 (8.3%) in group D. We recorded 30 complications, 22 of which were due to a conflict with the screw head, 18 (34.5%) in group A and 4 (8.3%) in group D (p = 0.03). Conflict between the screw head and the heel led to the removal of the screw after consolidation of the arthrodesis. The clinical results were evaluated using Odom's criteria. Nine per cent of patients described their results as excellent, 29% as good, 51% as satisfactory and 11% found the result to be poor. The fusion rate for isolated compression screw arthrodesis is good, and there is no difference between anterograde and retrograde screws. However, the discomfort caused by the screw head being insufficiently embedded in the retrograde group led to a non-negligible number of additional surgeries to remove the screw.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.