Abstract
The purpose of the research is an experimental substantiation of the methodology for determining ash content by the X-ray radiometric method. A brief overview of modern methods of coal ash content control is given. One of the independent directions of solid fuel quality control is the X-ray radiometric method. To increase the accuracy of determining the ash content of coal, a technique using two sources is proposed. The proposed method, using secondary radiation backscattered by coal and fluorescent radiation of elements, gives better results than the well-known method for determining ash content by backscattered radiatio
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.