Abstract
Autofluorescence imaging (AFI) is used as a ‘red flag' technique during Barrett's surveillance to identify subtle abnormal lesions which are not evident in high resolution white light endoscopy (HRE). This technique was found to have significant false positive results, but the sensitivity remains high. The aim of this study was to assess the interobserver agreement in detecting dysplastic lesions and to assess the overall accuracy of AFI among expert endoscopists. Anonymised AFI and HRE images were prospectively collected from patients undergoing Barrett's surveillance and dysplasia work-up. The AFI images were presented on power point in random order, followed by corresponding HRE and AFI images in a second folder. Three expert endoscopists (>150 AF endoscopies) scored the work sheet on separate occasions after an automated training presentation. The inter-observer agreement was calculated using kappa values (bias corrected) and the accuracy was calculated with histology as gold standard. 74 sets of anonymised white light and AFI images were prospectively collected from 63 patients (48 males, mean age 69). The inter-observer agreement for number of AF lesions noted was fair with a Kappa value of 0.39 (95% CI 0.28-0.52) for AFI images which improved significantly (p=0.04) to moderate kappa (0.57 and 95% CI 0.44-0.7) when corresponding AFI and HRE images are presented side by side. The inter-observer agreement for the quadrant with most significant AF lesion was moderate with a kappa of 0.48 (95% CI 0.37-0.6) which improved (p=0.08) to substantial kappa 0.62 (95% CI 0.50-0.72) when corresponding images were presented. The sensitivity for dysplasia detection was 0.75 (95% CI-0.68-0.81) and 0.84 (95% CI 0.78-0.89) using AFI images alone and using corresponding images respectively. Similarly, the specificity was 0.76 (95% CI 0.71-0.81) and 0.85 (95% CI 0.8-0.89). The overall accuracy of detecting dysplasia was 0.76 (95% CI 0.7-0.81) using AFI images alone and 0.85 (95% CI 0.79-0.89) using corresponding HRE and AFI images. The inter-observer agreement for dysplasia detection in Barrett's oesophagus using AFI images alone is only moderate among expert endoscopists, although it improved with addition of HRE. The overall accuracy of dysplasia using AF imaging was reasonable. Better understanding and recognition of what constitutes an AF positive signal on the endoscopic images is needed to improve this technique.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.