Abstract

Purpose: To compare the consistency and accuracy of a gradient-based algorithm (GRADIENT) with a constant threshold algorithm (THRESHOLD) for delineating positron emission tomography (PET) spheres of varying size and source-to-background ratio (SBR). Method and Materials: PET scans were acquired for cylindrical phantoms with fillable spheres on five different scanners including GE, Phillips and Siemens, emulating clinical conditions with different contrast levels to illustrate the influence of SBR. The phantoms were segmented from the scans using the GRADIENT and 37% constant threshold algorithm. The radii calculated from both methods were compared to the known actual radii of the phantoms in order to quantify the accuracy of each algorithm. Results: The gradient-based algorithm performed consistently across different scanners and with varying SBR and phantom size while the performance of the constant threshold algorithm deteriorated with decreases in both SBR and phantom size. For the gradient-based algorithm, the mean of the absolute radius percentage differences for the phantoms less than 10mm in size was 8.16% and the standard deviation was 0.1 whereas for the constant threshold algorithm the mean of the absolute percentage differences for the same phantoms was 55.98% and the standard deviation was 0.46. The statistics for the phantoms larger than 10mm in size were 3.84%, 0.03 and 8.45%, 0.05, respectively. Similar trends in percentage difference appeared for the same scanner and phantom set when the SBR decreased from 70:1 to 2:1. GRADIENT was robust to user initialization and resulted in less than 5% difference over several measurements for the same tumor. Conclusion: The gradient-based algorithm is more robust resulting in consistent results across different scanners and better accuracy than the constant threshold algorithm when evaluated in terms of varying SBR and phantom size for the in-vitro phantom studies. Conflict of Interest: Contributing authors employed by MIMvista Corporation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.