Abstract

According to the current technical problems existing in gas and liquid flow measurement for wet gas production, the slotted orifice-couple flow meter was developed and the basic measurement principles for gas and liquid flow was presented. A new wet gas flow meter was developed based on the dual slotted orifice transducer. The flow characteristics of liquid flow through dual slotted orifice plate, the relationship of differential pressure between the dual slotted orifice plate, pressure, temperature, and flow rate of gas/liquid of different aperture ratio were studied. A mathematical measurement model was established to be applied in the flow meter measurement system with dual slotted orifice plate. The model was tested and calibrated by on-site field experiments in the China National Center of Metrology at Daqing Oil field. The results showed that the maximum measurement error of the gas and liquid flow was less than 10% and 15% respectively, when the Gas Volume Fraction (GVF) was greater than 90 vol%. The measurement accuracy of this industrial prototype can meet the requirements of well fluids.