Abstract
In view of the current technical problems existing in multiphase flow metering, slotted orifice-couple flow meter was introduced and the basic principles for measurement were presented. A new wet gas flow meter is developed based on the dual slotted orifice. The flow characteristic of liquid flowing through dual slotted orifice plate, relationship of differential pressure between the dual slotted orifice plate, pressure, temperature, and flow rate of gas/liquid of different aperture ratio were studied. The mathematical measurement model applicable to the dual slotted orifice plate flow meter measurement system was established. The model was applied to onsite experiment and the calibration of China National Center of Metrology at Daqing Oil field. The results showed that the maximum measurement error of the gas phase flow was less than 10% and that of the liquid phase flow was less than 15%. The measurement accuracy of this industrial prototype can meet requirement of practical production.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.