Hydrophilic interaction liquid chromatography (HILIC) is an effective technique for separating polar compounds. But its retention equation has not been studied systematically yet. In this study, an appropriate retention equation was established by using eight nucleosides as model analytes and by comparing four retention models on six different HILIC columns. As a result, retention equation In k = a + b × In C B + c × C B could be quantitatively described the retention factors with good accuracy in HILIC mode. Based on this equation, the retention times of eight nucleosides under the conditions by other mobile phase can be predicted on each column. All of the predicted relative errors of retention times were smaller than 5%. The established retention model was also successfully applied to predict retention times of the real Traditional Chinese Medicine— Carthaus tinctorius L. sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.