Abstract

Abnormal vibration may occur in the pipeline of cooling and lubrication system of synchronous condenser during operation. In order to solve this problem, a priori analysis method for abnormal vibration of synchronous condenser piping system is proposed in this paper. This method mainly includes three parts :(1) the modal analysis of the whole pipeline system is carried out to find the pipeline with the most dangerous abnormal vibration; (2) Analyze the cause of abnormal vibration of the hazardous pipeline; (3) According to the analysis results of vibration causes, the field measurement is carried out, the modal analysis is verified, and then the cause and location of abnormal vibration of the whole pipeline system are determined. The results of case analysis show that this scheme can quickly and accurately find out the cause and location of abnormal vibration of the synchronous condenser pipeline system, improve detection efficiency and save cost. At the same time, the natural frequency of vibration obtained by modal analysis can provide a theoretical basis for the design and transformation of the synchronous condenser pipe system.