Abstract
Undoped semi-insulating gallium arsenide and iron (Fe)-doped indium phosphide radiation detectors have been fabricated. The electrical characteristics (I–V and C–V) of the detectors have been carried out at room temperature under dark conditions. By analysing the I–V characteristics of the detectors, the barrier height, ideality factor and reverse leakage current have been evaluated. The SI-GaAs detector has been tested using 241Am alpha particle source of 5.48 MeV energy under a vacuum of 1×10−3 Torr at room temperature. An alpha energy resolution of 6% has been obtained. The detector charge collection efficiency was measured using the source and was found to be 98%. The SI-InP detector has been tested using 57Co(122keV) and 137Cs(662keV) gamma sources and the energy response of the InP detector has been analysed. In this article, details on the performance of our SI-GaAs and SI-InP surface barrier detectors for alpha- and gamma-ray detection are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.