Abstract

Purpose Under normal conditions, there are different protection objects inside and outside the gas station, so two sets of independent cathodic protection systems are adopted. At the same time, an insulating flange is applied at the position where trunk pipelines access to the gas station, which realizes electrical isolation of the structures inside and outside the station. However, as a result of short distance between the two cathodic protection systems, there will be stray current interference between them. The purpose of this paper was to study on the interference between cathodic protection systems of gas station and long distance trunk pipeline. Design/methodology/approach Based on the above, in this paper, first, the mathematical model of interference between cathodic protection systems was established and the control equations solved using the boundary element method. Second, the influence of cathodic protection system of gas station on long distance trunk pipeline and the influence of cathodic protection system of long distance trunk pipeline on gas station were studied separately using BEASY software. Finally, a new thought of cathodic protection design for local station was put forward. Findings It was concluded that there were serious interference problems between the cathodic protection systems of gas station and long distance trunk pipeline. By moving the potential control point to area outside the influence scope of anode ground bed could avoid the influence of cathodic protection system of gas station on long distance trunk pipeline. By moving the auxiliary anodes away from gas station could avoid the influence of cathodic protection system of long distance trunk pipeline on pipelines in gas station. The new thought of cathodic protection design could avoid the interference between the cathodic protection systems effectively. Originality/value It is considered that the results can guide cathodic design for gas station and long distance trunk pipeline. The results can also avoid the interference corrosion between the structures in gas station and trunk pipeline.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.