Abstract

The HTV SIR provided the superior hydrophobicity for the composite insulator. But it faces the aging problem more than the inorganics. Corona, as an inevitable influence factor in insulator’s operation, its effect to the material could not be ignored. The paper developed a multi needles to plate corona aging equipment, 1000 hours’ corona aging to the HTV SIR was done. The duration of corona aging effect was study by FTIR, SEM and volume resistivity-temperature character testing. Three testing methods from the aspect of material’s chemical, physical and electrical characters to evaluate the aging effect with time went on. It had good consistency in all three methods for HTV SIR’s corona aging evaluation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.