Abstract

This paper discussed the problem that parameters of bone external fixator are difficult to calculate in the practical application. Positive solution is described in detail. We used MATLAB software to make simulation experiment. The innovation lies the development idea of using inverse position to verify the accuracy of positive solution. Forward displacement analysis was mainly developed using analytical method, which has many advantages, such as small dependence to the inverse solution and the higher precision. With further software development, we will have the algorithms; research model and interface program connected and form high precision smart compliance multifunctional bone external fixator products, which will greatly enhance the overall level of bone external fixation technology and clinical application treatment.

Highlights

  • IntroductionIn order to increase the level of clinical application of the bone external fixator, this title discuss the problem of the solution in calculating parameters in the background of related software of bone external fixator which has self-property right

  • In order to increase the level of clinical application of the bone external fixator, this title discuss the problem of the solution in calculating parameters in the background of related software of bone external fixator which has self-property right.Bone external fixator uses the Taylor structure in practical application

  • This study can regard as the inverse solution and positive solution of the Stewart platform[3,4,5].Fig.1 shows the application of Stewart platform in femur correction

Read more

Summary

Introduction

In order to increase the level of clinical application of the bone external fixator, this title discuss the problem of the solution in calculating parameters in the background of related software of bone external fixator which has self-property right. When adjusting the length of the studdle, the relative location of the two hoops changes This Taylor structure can regard as Stewart platform[1,2]. This study can regard as the inverse solution and positive solution of the Stewart platform[3,4,5].Fig. shows the application of Stewart platform in femur correction.

Modeling
Positive solution algorithm
Summary
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.