Abstract

In direct current (dc) transmission lines, power cables are susceptible to the invasion of switching overvoltage or lightning overvoltage. This causes the accumulation of space charge in the insulation due to the higher transient composite electric stress. Space charge is an important factor in dielectric breakdown, especially under high electric stress. However, until now, there are few reports on space charge characteristics under the composite stresses of dc voltage and impulse voltage. In this article, a modified pulsed electroacoustic space charge measurement system used for dc voltage superimposed by impulse voltage is developed by reasonably choosing resistor and capacitor elements in the measuring system. Then, space charge characteristics in cross-linked polyethylene (XLPE) are measured under dc voltage, impulse voltage, and dc voltage superimposed by impulse voltage. The test results show that hetero-charges dominated in the XLPE bulk under a positive dc voltage, whereas homo-charge injection occurred from the semiconductor (SC) electrode under a negative dc voltage. However, a continuous impulse voltage with high amplitude can cause a large degree of homo-charge injection from both electrodes. Moreover, greater homo-charge injection appeared under the negative impulse voltage than that under the positive impulse voltage. Under a dc voltage superimposed by an impulse voltage, the superposition of voltages with the same polarities facilitated homo-charges injection from both electrodes to a greater extent than did the superposition of voltages with opposite polarities. Furthermore, regardless of the polarity of the applied dc voltage, greater space charge accumulation appeared in XLPE when a negative impulse voltage is superimposed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call