Abstract

The evacuation channel of the Metro tunnel serves as a corridor for the evacuation of two Metro tunnels. The trapped people need to open two fire doors at both ends of the evacuation channel. However, the fire door is a one-way fire door, and the narrow one can only be passed by one person, which is easy to cause people to block and reduce the evacuation efficiency. Therefore, it is proposed that no fire doors should be set in the evacuation channel, the accident tunnel uses the push-pull air supply mode, and the non-accident tunnel uses the double-side air supply mode strategy for smoke control. Through experimental research, it is concluded that: This mode can effectively control the flue gas and prevent the flue gas from entering the non-accident tunnel. At the same time, the fresh air of the control system has good cooling effect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.