Abstract

Minimum substrate loss is required for resist strip of high dose, ultra shallow junction implant for source/drain extensions. Silicon surface oxidation of downstream plasma resist strip results in silicon recess of the source/drain extension regions. This paper reports the study of silicon surface oxidation for different resist strip plasma chemistries and the effect of plasma strip process parameters such as power, pressure and temperature on silicon surface oxidation. A good agreement was found between optical ellipsometry, XPS (X-ray photoelectron spectroscopy) and TEM (transmission electron spectroscopy) for thickness measurement of very thin (<20 Å) oxide grown on silicon surface due to plasma exposure. Selectivity of crust breakthrough and resist removal over silicon oxidation was also discussed in this paper along with dopant loss.