Abstract
To improve the filtration efficiency of the dual-layer granular bed filter, a new method to enhance filtration with dust bipolar-charging was proposed. The characteristics of positive and negative corona discharge and dust charging at different temperatures were measured and analyzed. The filtration experiments of non-charged dust, positive charged dust, negative charged dust, and bipolar charged dust in a dual-layer granular bed filter were carried out. The results confirmed that the best filtration effect was achieved when the dust was bipolar-charged. Furthermore, because of the loose structure of dust cake formed by the charged dust, the filter regeneration cycles were prolonged. At 450 ℃, when the inlet dust concentration was 10 g/m3, and the bi-charging voltages were + 20 kV and - 14 kV, the mean outlet dust concentration in a filtering cycle was 38.1%, 46.6% and 68.2% lower than that of negative-charged, positive charged, and non-charged dust, respectively.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.