Abstract

The experimental system of 10 m3 large-scale multiphase combustion explosion tank was used for research into the explosion development process under the ignition conditions of methane-coal dust-air mixture, and the overpressure development processes of the mixture at different distances were obtained. For the methane-coal dust-air mixture with an equivalence ratio of 1, the explosion pressure and pressure rise rate reached their maximum under a methane concentration of 8% and a coal dust concentration of 25 g/m3, while the maximum explosion pressure and pressure rise rate both occurred 0.5 m away from the ignition point under a methane concentration of between 4.5% and 8%, and a coal dust concentration of between 25 g/m3 and 100 g/m3. Moreover, the greater the explosion intensity of mixture, the closer the occurrence location of maximum overpressure was to the ignition source.