Abstract
In terms of the deficiency of the existing research on the compression load and energy absorption characteristics of composite structures, a glass fiber honeycomb tube with different thickness and different cell number was proposed. The static compression test was carried out by universal testing machine. The results show that the failure forms of honeycomb tube are fiber fracture damage, fiber layer delamination and their composite forms. The peak compression load and total energy absorption increase with the increase of cell number and thickness, and the specific energy absorption increase only with the increase of thickness. The compression peak load of single-cell honeycomb tube with wall thickness of 0.4 mm is the smallest, which is 2.21 KN; and the compression peak load of eight-cell honeycomb tube with wall thickness of 1.2 mm is the largest, which is 91.48 KN. The corresponding total energy absorption is 25.16 J and 2257.57 J respectively; the corresponding specific energy absorption is 8.38 J/g and 45.06 J/g respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.