Abstract

Coal spontaneous combustion is a common problem faced by many coal mines. Spontaneous combustion in goaf releases a large amount of harmful gases, polluting the environment while causing a large amount of wasted resources, and even endangering the lives of workers. Due to the collapse of the interior of the mining area, it is impossible to measure the internal gas composition directly. In order to more accurately predict the spontaneous combustion state inside the mining airspace, this paper obtains the CO generation law and the main source of the working face through the combination of laboratory experiments and on-site monitoring. The CO concentration prediction model of the return corner is established with CO as the index gas. Finally, the safe concentration and warning concentration of the working face are calculated according to the example, which provides theoretical basis for the prediction of spontaneous combustion of coal.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call