Abstract
The limestone-gypsum wet desulfurization wastewater was studied in this paper, and the biological treatment method was proposed for the problem that the water quality of the desulfurization wastewater after the physicochemical treatment was still not up to standard. In this experiment, the domestic sewage of a power plant was added into the desulfurization wastewater to make the desulfurization wastewater biodegradable, then SBR biological treatment was carried out to make the effluent water quality met the relevant requirements of Sewage Discharge Standard (GB8978-1998) and Water Quality Control Index of Limestone - gypsum Wet Desulfurization Wastewater of Thermal Power Plant (DL/T 997-2006).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.