Abstract

The analysis of entering water samples, gave an average value for pH (7.98), but yielded water samples show a slight change in the pH (8.06), while the value of conductivity EC for sea water was (53501µs/cm), then, significant decrease has been recorded in yielded water samples to become (32.032µs/cm). The chemical analysis also showed a major difference in the measurement for both of total dissolved salts TDS, and salts causing hardness TH, between entering and yielded water samples, as same as for sodium and potassium, where the average value of their concentrations in water samples that goes inthe desalination plant were (10380ppm)&(444ppm), to become (5.358ppm)&(0.24ppm)in water that goes outof desalination plant, respectively. A big difference was also observed in the average concentration of chloride and sulfate anions, in which the amount of chlorine was (19644ppm)and for sulfate (2752ppm)insea water, however at yielded water bothof them were (2.292ppm)and (1.389ppm)respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.