Abstract
Some performances of an excimer discharge at the formative stage are calculated and compared to the experimental results obtained in a XeCl* laser device with a pin cathode without external preionization. We present a simplified discharge model for exploring the process of the preionization generated by the coronas in the cathode pin region.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.