Abstract

The simulation of electrical machines at the first design stage requires efficient methods to characterize among other properties its vibrational behavior. Particularly when considering both designed and parasitic geometrical modifications, magnetic circuit calculations of large-dimensioned machines by finite-element methods (FEM) are cumbersome. Semi-analytical approaches by means of conformal mapping are therefore useful to estimate the impact of several effects, such as asymmetric stator laminations, rotor pole shapes and air gap imperfections. No-load operation is studied and the presented approach is validated by FEM simulations. The aim of this work is to study force excitations by the magnetic air gap field in salient multi-pole synchronous generators deviating from ideal and symmetrical geometrical conditions by using conformal maps.