Abstract
This article presents data collected by measurements of lead (Pb) and iron (Fe) and their combination as heavy shielding materials. Measurements were performed using gamma photon energies of 662, 1173, and 1332keV for the Cs-137 and Co-60 sources. The theoretical data part was calculated using WinXCom, Phy-X, and Py-MLUBF software packages. Tables and graphs of the photon Mass Attenuation Coefficient (MAC), Linear Attenuation Coefficient (LAC), Half Value Layer (HVL), Tenth Value Layer (TVL) and Mean Free Path (MFP) are presented for both heavy metals and their combination to study the shielding properties experimentally and theoretically. The results will contribute to the ongoing research as a database for future use.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Engineering, Technology & Applied Science Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.