Abstract

This article aims to simulate the sudden and fast pressure drop of VVER-1000 reactor core coolant, regarding acoustic phenomenon. It is used to acquire a more accurate method in order to simulate the various accidents of reactor core. Neutronic equations should be solved concurrently by means of DRAGON 4 and DONJON 4 coupling codes. The results of the developed package are compared with WIMS/CITATION and final safety analysis report of Bushehr VVER-1000 reactor (FSAR). Afterwards, time dependent thermal-hydraulic equations are answered by employing Single Heated Channel by Sectionalized Compressible Fluid method. Then, the obtained results were validated by the same transient simulation in a pressurized water reactor core. Then, thermal-hydraulic and neutronic modules are coupled concurrently by use of producing group constants regarding the thermal feedback effect. Results were compared to the mentioned transient simulation in RELAP5 computer code, which show that mass flux drop is sensed at the end of channel in several milliseconds which causes heat flux drop too. The thermal feedback resulted in production of some perturbations in the changes of these parameters. The achieved results for this very fast pressure drop represent accurate calculations of thermoneutronic parameters fast changes.

Highlights

  • One of the most important aspects in design of different safety systems with sufficient preparation is simulation and analysis of transient states in reactor core

  • Power Peaking Factor is compared to WIMS/ CITATION [19] and Bushehr VVER-1000 reactor FSAR value [18], as observed

  • After the defined model is validated, thermal-hydraulic module preparation is started based on single heated channel (SHC) by sectionalized compressible fluid (SC) method

Read more

Summary

Introduction

One of the most important aspects in design of different safety systems with sufficient preparation is simulation and analysis of transient states in reactor core. For these kinds of analysis basic equations in neutronic and thermal-hydraulic modules have to be coupled. Coupling of neutronic and thermal-hydraulic modules is different from each other, considering numerical solution methods and time and body meshing size. Most codes are not able to analyze coupled conditions of very fast transient (FT) states in very short time. This deficiency is associated with neutronic and thermal-hydraulic calculations or both

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.