Abstract

In this study, refinery wastewater treatment scheme, the electro-Fenton oxidation process is obtainable. Through Fenton oxidation treatment, numerous working limits remained examined, for instance hydrogen peroxide, electrolysis time and pH. The effects of the working variables including the pH (2-9), hydrogen peroxide concentration (20-60 mg/L) and the reaction time (10-30 minutes) and remained thoughtful through means of answer surface methodology and Minitab-17. The current, agitation speed and sodium chloride of the aqueous solution consumed remained engaged as 1 Amps, 200 rpm and 0.2 g congruently. Beneath the finest standards of the employed variables extra than 98% oil removal in refinery wastewater.