Abstract

Position resolution and lifetime have been studied for one-atmosphere DME in half-inch diameter aluminum tube chambers operated in the limited streamer mode. The radial resolution was measured by timing to be σ r = 73 μm. The longitudinal resolution was measured by charge division to be <0.3% of the wire length. No significant gain changes were seen after 12 C/cm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.