Abstract

The electronic equipment for control of different systems of Units 5 and 6 is studied for presence of degradation processes occurring in result of continuous usage in conditions of controlled radiation background in compliance with “Kozloduy” NPP safety codes. Systems, operated in a continuous mode in the course of about 10 years were chosen — separate units containing different dielectric materials (varnish coating, circuit board bases, cable insulations, electro protective elements, etc.) were extrapolated. Series of test samples were prepared which were connected with flat or coaxial condensers and their characteristic parameters were measured: tgδ, ε, low voltage conductivity and leak currents at voltages that exceed the working ones several times. When comparing the obtained data with the reference ones, a conclusion is made about the effectiveness of electric ageing during operation in the course of time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.