Abstract
The present experimental paper is officiated to study the heat characteristics and performance of air flow through a square cross-sectional heated channel under natural heat convection conditions. The influence of baffles arrangement and perforated baffles on the rate of heat transfer through a channel are studied. Four cases of a heated channels are studied, one is a plain channel and other three channels with a baffle namely, three inline baffles, three staggered baffles and three staggered perforated baffles arrangements. The outer tested channels surfaces are electrically heated with a constant surface heat flux condition. All tested channels are fabricated by cold forming with constant dimensions using aluminum plate has thickness of 1.0 mm. The heat performance is assessed for all tested channels. The results of present paper are approved than the available data in the previous paper and a good convergence are noticed. Obtained experimental results appear that a three staggered perforated baffles arrangement is a best selection as it improves heat transfer rate in expression of Nusselt number, it higher about 22% to 27% than that the plain channel for same conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.