Abstract

A novel two-tube, two-stage, self-compensating resistive voltage divider with minimized stray capacitance using copper sulphate solution was explored to measure a fast high-impulse voltage output from a cable Blumlein generator. Self-compensation of the probe was achieved by matching the RC time constant in the two dividing stages. Stray capacitance of the probe was minimized by electric field contouring and matching methods. Experiments were carried out to investigate the probe responses as affected by self-capacitance, impedance, and stray capacitance. Calibration of the optimized probe showed a rise time of 15 ns at a load impedance of 8.68 kΩ with a hold-off voltage of 600 kV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.