Abstract

The corrosion status and results in a certain water injection station in Shanbei oilfield were monitored and evaluated by flow corrosion test (FCT) (with homemade corrosion test device), static corrosion test (SCT), and water tank corrosion test (WTCT). The coupons after corrosion tests were observed by Scanning Electron Microscope (SEM). It was found that: the corrosion rates of SCT, FCT and WTCT were 0.0469~0.0552 mm/a, 0.5126~0.5299 mm/a, and 0.3250~0.3414 mm/a respectively; the corrosion rates SCT were much smaller than actual. The severity of pitting corrosion, pointed corrosion and other forms of local corrosion cannot be reflected by SCT. The corrosion rates and behaviors tested by homemade corrosion test device are more close and similar to the real.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.